Grand Hotel National Luzern
HotelOverall assessment accessibility Partially accessible
Self-declared content
This content was verified by the operator of the service.Check the accessibility of this location
Rooms
Visitor parking
Criteria
-
Parking space
Regular parking spaceDetails Regular parking space - Designation Regular parking space
- Orientation Sideways
- Width of parking space 230 cm
- Length of parking space 500 cm
- Slope 0 %
- Number of parking spaces of the same type 7
- Distance to entrance 7 m
-
Ground condition
Ground conditionDetails Ground condition - Material Paving stones
- Driving characteristic Uneven / bumpy
- Reflective surface No
Terrace
Access criteria
-
Access from Lobby
Ramp (on request)/ElevatorDetails Ramp (on request) - Type of ramp Upon request
- Slope 12 %
- Length of ramp 800 cm
- Width of ramp 150 cm
Elevator - Type of door Automatic door
- Door width 95 cm
- Cab width 120 cm
- Cab depth 205 cm
- Height of the highest relevant operating elements 120 cm
- Load capacity 1000 kg
- Length of hallway near elevator 240 cm
- Width of hallway near elevator 200 cm
- Key required No
- Mirror Available
Criteria
-
Table
Table is not accessible, Table is not accessibleDetails Table is not accessible - Clearance height under table 68 cm
- Clearance depth under table 35 cm
- Tabletop height 74 cm
- Bench Movable
- Chair Movable
Table is not accessible - Clearance height under table 70 cm
- Clearance depth under table 37 cm
- Tabletop height 73 cm
-
Space conditions
Lots of space -
Ground condition
Ground conditionDetails Ground condition - Material Tile flooring
- Driving characteristic Flat / Solid
- Reflective surface No
Spa
Access criteria
-
Access from Lobby
Ground-level, ElevatorDetails Ground-level - Landing height 0 cm
- Handrail Not available
- High contrast marking No
Elevator - Type of door Automatic door
- Door width 80 cm
- Cab width 115 cm
- Cab depth 90 cm
- Height of the highest relevant operating elements 120 cm
- Load capacity 400 kg
- Length of hallway near elevator 200 cm
- Width of hallway near elevator 200 cm
- Key required Yes
- Mirror Available
- Handrail Not available
- Support for the visually impaired None
Criteria
-
Space conditions
Limited spaceDetails Limited space - Narrowest relevant point 80 cm
- Length of the area 90 cm
- Width of the area 110 cm
Dining hall
Access criteria
-
Access from Lobby
Ground-levelDetails Ground-level - Landing height 0 cm
- Handrail Not available
- High contrast marking No
Criteria
-
Table
Table is accessibleDetails Table is accessible - Clearance height under table 70 cm
- Clearance depth under table 80 cm
-
Space conditions
Limited space
Toilets
Access criteria
-
Access from Lobby
ElevatorDetails Elevator - Type of door Automatic door
- Door width 95 cm
- Cab width 120 cm
- Cab depth 205 cm
- Height of the highest relevant operating elements 120 cm
- Load capacity 1000 kg
- Length of hallway near elevator 240 cm
- Width of hallway near elevator 200 cm
- Key required Yes
- Mirror Available
Criteria
-
Toilet
Accessible ladies’ roomDetails Accessible ladies’ room - Gender Women
- Height of toilet bowl 45 cm
- Free space in front of toilet bowl 90 cm
- Longest free distance next to WC bowl 102 cm
- Distance to sink 30 cm
- Available resources Fold-down handle, L-shaped handle on the wall
-
Washbasin
Not accessible, Not accessibleDetails Not accessible - Clearance height under sink 87 cm
Not accessible - Clearance height under sink 85 cm
-
Space conditions
Limited spaceDetails Limited space - Narrowest relevant point 80 cm
- Length of the area 10 cm
-
Baby changing table
Available in ladies’ roomDetails Available in ladies’ room - Availability Available
- Gender Women
Hotel room
Sub-areas
Classic Zimmer, Stadtseite
AccessSuperior Zimmer, Stadtseite
AccessClassic Zimmer, Seeseite
AccessSuperior Zimmer, Seeseite
AccessDeluxe Zimmer, Seeseite
AccessEmpire Junior Suite, Seeseite
AccessRitz Suite, Seeseite
AccessLobby
Access criteria
-
Access from Street
Ramp (on request), Elevator, Side entranceDetails Ramp (on request) - Type of ramp Upon request
- Slope 12 %
- Length of ramp 800 cm
- Width of ramp 150 cm
- Roofing Available
- With directional change Yes
Elevator - Type of door Automatic door
- Door width 95 cm
- Cab width 120 cm
- Cab depth 205 cm
- Height of the highest relevant operating elements 120 cm
- Load capacity 1000 kg
- Length of hallway near elevator 240 cm
- Width of hallway near elevator 200 cm
- Mirror Available
- Handrail Available
Yes - upon request - Barrier-free access via side entrance Yes, upon request
-
Access from Visitor parking
Ramp (on request), Elevator, Side entranceDetails Ramp (on request) - Type of ramp Upon request
- Slope 12 %
- Length of ramp 800 cm
- Width of ramp 150 cm
Elevator - Type of door Automatic door
- Door width 95 cm
- Cab width 120 cm
- Cab depth 205 cm
- Height of the highest relevant operating elements 120 cm
- Load capacity 1000 kg
- Length of hallway near elevator 240 cm
- Width of hallway near elevator 200 cm
- Key required No
- Mirror Available
Yes - upon request - Barrier-free access via side entrance Yes, upon request
Criteria
-
Customer service counter
Standing counterDetails Standing counter - Clearance height under table 112 cm
- Tabletop height 112 cm
- Clearance depth under table 112 cm
- Chair None
-
Waiting area
Waiting areaDetails Waiting area - Covered waiting area Yes
- Seating option Yes
- Electronic display None
- Acoustic information Disruptions
- Posting timetable No
- Obstacle-free access to information carriers Yes
-
Path characteristics
Path characteristicsDetails Path characteristics - Slope 0 %
- Path width 220 cm
-
Side entrance
Yes - upon requestDetails Yes - upon request - Barrier-free access via side entrance Yes, upon request
-
Toilet
Accessible ladies’ roomDetails Accessible ladies’ room - Gender Women
- Height of toilet bowl 45 cm
- Free space in front of toilet bowl 90 cm
- Longest free distance next to WC bowl 102 cm
- Distance to sink 30 cm
- Available resources Fold-down handle, L-shaped handle on the wall
-
Space conditions
Lots of spaceDetails Lots of space - Narrowest relevant point 220 cm
-
Baby changing table
Available in ladies’ roomDetails Available in ladies’ room - Availability Available
- Gender Women
Conference room
Criteria
-
Wheelchair space
AvailableDetails Available - Number of parking spaces 5
- Width of parking spaces 150 cm
- Length of parking spaces 150 cm
- Possible to sit next to companion Yes
-
Table
Table is not accessibleDetails Table is not accessible - Clearance height under table 72 cm
- Clearance depth under table 72 cm
- Tabletop height 72 cm
- Bench Fixed
- Chair Movable
Hall
Sub-areas
Stalls
Access, Wheelchair spaceAddress
Grand Hotel National Luzern
Haldenstrasse 4
6006 Luzern